Serial indicator with Modbus
Model IQ230
is a 6-digit panel-mount serial input remote indicator for RS232 and RS485.
Serial communications is supplied as standard with MODBUS™ RTU and MODBUS™ ASCII protocols. A simple ASCII-out protocol is also provided for serial printing, datalogging and large display interfacing.
Advanced features include max/min recording; programmable front pushbuttons; 2 programmable digital inputs; security menu lockout; and built-in menu help hints.
The alphanumeric high-bright LED display and programming help prompts makes for quick and easy set-up. Model IQ230 options include up to 4 relays, analogue retransmission, and real time clock for date and time stamping.
- High bright 6-digit 14-segment LED displays for easy setup and calibration
- -199999 to +999999 display counts
- RS232 and RS485 communications standard
- MODBUS™ RTU/ASCII and an Infiniteq ASCII out protocol
- IP65, NEMA 4, UL Type 4, 48 x 96mm ABS/Polycarbonate enclosure
- Universal AC and DC switch mode power supplies
- 2 x Programmable digital inputs (pull up or pull down field jumper selectable)
- 3 x Programmable front panel push buttons
- Up to 4 front panel LED indicators for alarm set point status (Mechanical or solid-state option required)
- Maximum/Minimum recording
- Built in menu help hints
- Field upgradable firmware via the RS232 interface
- 1 year warranty
| General: | Model IQ230 |
| Display | 6-digit, 13.8mm (0.543”) 14 segment high brightness red LED |
| Display range | -199999 to +999999 |
| Status LED's | 4 LED's for SP1 to SP4 |
| Digital Inputs | 2 Programmable digital inputs |
| Built in hysteresis, filter and input over voltage protection | |
| Maximum input voltage <30VDC | |
| Input logic is field jumper selectable | |
| (Pull up, sinking inputs) - 10kΩ internal resistor to 5V | |
| (Pull down, sourcing inputs) - 10kΩ internal resistor to common | |
| Active/Non-Active input trigger: <1.9V | |
| Non-Active/Active input trigger: >2.3V | |
| Keypad | 4 keys total, 3 programmable keys |
| Memory storage | Non-volatile EEPROM, 100000 write cycles minimum |
| Warm up time | 15 minutes |
| Power Requirements: | |
| AC Supply | 85-264VAC, 50/60Hz or 120-370VDC |
| Isolation: 3000VAC/1min | |
| Low DC Supply | 10-30VDC input |
| Reverse and over voltage protected | |
| Isolation: >1000V/1min | |
| High DC Supply | 25-70VDC input |
| Reverse and over voltage protected | |
| Isolation: >1000V/1min | |
| Power Consumption | <5W, depending on options selected |
| Fuse (built in) | 2A Slow Blow (Wickmann_3721200000) |
| RS components part number_2266599 | |
| Environmental: | |
| Operating temperature | -10°C to 50°C (14°F to 122°F) |
| Storage temperature | -40°C to 80°C (-40°F to 176°F) |
| Operating / storage humidity | <85% RH non-condensing |
| Enclosure: | |
| Overall Dimensions | 96 x 48 x 112mm (LxHxD) (3.78 x 1.89 x 4.41”) |
| (Depth includes connectors) | |
| Mounting | 92 x 45mm (3.62 x 1.77”) cut-out |
| Enclosure material | Rear ABS, Front polycarbonate |
| Front facia rating | IP65, with O-ring supplied as standard |
| Wiring connections | Removable terminal blocks |
| Analogue Out: | Optional |
| Ranges (selectable through menu) | |
| 0-20mA | |
| 4-20mA | |
| 0-10V | |
| DAC Resolution | 16 Bit |
| Update rate | 10 updates/second |
| Current output compliance | 500Ω maximum load |
| (Current is source, not sink) | |
| Voltage output compliance | 1kΩ (minimum load) |
| Current open loop detection | Display flashes “mA.Loop” error message |
| Linearity | <0.02% of full scale |
| Accuracy | 0.05% of full scale |
| Isolation (Optional) | 1000VDC @ 1mA for 1 minute |
| Communications: | |
| Protocol | MODBUS™ RTU |
| MODBUS™ ASCII | |
| ASCII In (Infiniteq Protocol) | |
| ASCII Out (Infiniteq Protocol) | |
| RS232 (standard) | Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Data bits: 7 or 8 bits | |
| Parity: Odd, Even or None | |
| Stop bits: 1 or 2 stop bits | |
| Non isolated | |
| RS485 (standard) | Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Data bits: 7 or 8 bits | |
| Parity: Odd, Even or None | |
| Stop bits: 1 or 2 stop bits | |
| Internal 120Ω field jumper selectable termination resistor | |
| Max 32 instruments per line | |
| Setpoint Relays: | Optional, 1, 2, 3 or 4 can be fitted |
| Electro-mechanical: | |
| Contact rating | 2A@240VAC or 30VDC (resistive load) |
| Isolation to input circuitry | >1000Vrms for 1 minute |
| Type | FORM-C (change over contact, NO / NC) |
| Life expectancy | >100K cycles min. at full load rating. External RC snubber extends relay life for operation with inductive loads |
| Solid-State (SSR): | |
| Contact rating | 120mA@400VAC/DC |
| Isolation to input circuitry | >1000Vrms for 1 minute |
| Type | FORM-A (normally open) |
| Real Time Clock: | Optional RTC |
| Battery | CR2032 |
| Accuracy | Better than 2 seconds per day (temperature dependent) |
Order codes and options:
IQ230 for 85-264VAC auxiliary supply
-700 10-30VDC auxiliary supply
-701 25-70VDC auxiliary supply
-710 1 mechanical change-over Form C relay
-711 2 mechanical change-over Form C relays
-712 3 mechanical change-over Form C relays
-713 4 mechanical change-over Form C relays
-720 1 solid-state Form A relay
-721 2 solid-state Form A relays
-722 3 solid-state Form A relays
-723 4 solid-state Form A relays
-730 16 bit analogue output, 0/4-20mA, 0-10V
-731 16 bit isolated analogue output, 0/4-20mA, 0-10V
-750 Real time clock
-760 Engineering units legends
-761 Power connector protective cover
-762 115VAC inductive load suppressor
-763 230VAC inductive load suppressor
-764 2A slow-blow panel meter replacement fuse
-765 R-C snubber noise and arc suppressor
-766 Transparent protective front cover
IQ230 6-digit panel mount serial MODBUS indicator
IQ230 serial input indicator functions