Wall Mount Belt Weigher
IQ320 has an internal jumper selectable power supply for powering shaft encoders, tacho-generators or pulse counting proximity switches for belt conveyor speed measurement.
Advanced features include auto-zero tracking; user input linearisation; max/min recording; programmable front pushbuttons; 3 programmable digital inputs; security menu lockout; motion indication; advanced digital filtering; automatic offset calibration; plus many more to provide an all-in-one precision load cell indicator.
RS232 and RS485 serial communications are standard with MODBUS™ RTU and MODBUS™ ASCII protocols. A simple ASCII-out protocol is also provided for serial printing and communicating to large displays.
Model IQ320 includes 4 electromechanical relays, 16-bit analogue retransmission and a Real Time Clock.
- High bright 6-digit 20mm LED display
- Backlit 4-line graphic LCD for easy setup and calibration
- 4 or 6 wire load cell / strain gauge input
- Powers up to 6 x 350Ω load cells
- 5V or 10VDC excitation voltage
- Dynamic Tare function
- Dynamic Calibration function
- Deadband adjustment for minimum totalising rate
- Encoder / pulse input with jumper selectable excitation
- Resettable and non-resettable totalisers
- High precision 22 bit ratiometric ADC front end circuitry
- -199999 to +999999 display counts
- Easy calibration using known weights or load cell data
- 16 Bit Analog output (0/4-20mA or 0-10V)
- RS232 communications (MODBUS™ RTU / ASCII and Infiniteq ASCII protocols)
- RS485 communications (MODBUS™ RTU / ASCII and Infiniteq ASCII protocols)
- 3 Programmable digital inputs (pull up or pull down field jumper selectable)
- 3 Programmable front panel push buttons
- 4 Form-C alarm relay setpoints
- Cage-clamp wire connectors
- 16 Point lineariser
- Pulse counting output
- 8 front panel status LED's
- Selectable and adjustable advanced digital filtering
- Alarms, Motion indication and Net front panel status LED's
- Max / Min recording
- Security menu lockout
- Built in menu help hints and prompts
- Field upgradable firmware via the RS232 interface
- 1 year warranty
| General: | Model IQ320 |
| LED display | 6-digit, 20mm (0.8”) 7 segment high brightness red LED |
| LCD display | 128 x 64 graphic mono sunlight readable |
| Backlight | Yellow / Green with on/off control |
| Display range | -199999 to +999999 |
| Decimal point | 0 to 0.00000 |
| Status LED's | 8 LED's for SP1 to SP4, Rate, Total, Dead Range & Print |
| Digital Inputs | 3 Programmable digital inputs |
| Built in hysteresis, filter and input over voltage protection | |
| Maximum input voltage <30VDC | |
| Input logic is field jumper selectable | |
| (Pull up, sinking inputs) - 10kΩ internal resistor to 5V | |
| (Pull down, sourcing inputs) - 10kΩ internal resistor to common | |
| Active/Non-Active input trigger: <1.9V | |
| Non-Active/Active input trigger: >2.3V | |
| Keypad | Full 4 x 3 alphanumeric |
| 4 Dedicated function keys (Zero, Tare, Print, Gross/Net toggle) | |
| 3 Dual function keys (Display Toggle, Display Hold & Alarm latch reset) | |
| Memory storage | Non-volatile EEPROM, 100000 write cycles minimum |
| Warm up time | 15 minutes |
| Power Requirements: | |
| AC Supply | 85-264VAC, 50/60Hz or 120-370VDC |
| Isolation: 3000VAC/1min | |
| Low DC Supply | 10-30VDC input Reverse and over voltage protected Isolation: >1000V/1min |
| High DC Supply | 25-70VDC input Reverse and over voltage protected Isolation: >1000V/1min |
| Power Consumption | <15W |
| Fuse (built in) | 2A Slow Blow (Wickmann_3721200000) |
| RS components part number_226-6599 | |
| Environmental: | |
| Operating temperature | -10°C to 50°C (14°F to 122°F) |
| Storage temperature | -40°C to 80°C (-40°F to 176°F) |
| Operating / storage humidity | <85% RH non-condensing |
| Enclosure: | |
| Overall Dimensions | 180 x 180 x 60mm (LxHxD) (7.09 x 7.09 x 2.36”) |
| (Height includes cable glands) | |
| Mounting holes | 159 x 94mm (6.26 x 3.70”) |
| Enclosure material | ABS - Flame retardant (UL 94 V-0) |
| IP rating | IP65 / NEMA 4 / UL Type 4 |
| Connection type | Cage clamp wire connectors |
| Input: | |
| ADC Resolution | 22 bit Delta-sigma |
| Input range | -20mV to +35mV |
| Conversion rate | 12 updates/second |
| Filter | Moving average digital filter with programmable input step detection |
| Increment size | 1, 2, 5, 10, 20, 50, 100, 200 |
| Input Impedance | >20 MΩ |
| CMRR | >-110dB |
| Linearity | <0.01% of full scale |
| Accuracy | 0.05% of full scale |
| Calibration method | From the load cell calibration certificate or using known weights |
| Load cell connection | 4 or 6 wire connection + shield (sense included) |
| Load Cell Excitation: | |
| Excitation Voltage | +5VDC fixed |
| Excitation current | Maximum 90mA |
| Up to 6 x 350Ω or 10 x 1000Ω load cells | |
| Cable compensation | Ratiometric |
| Encoder / Tacho-generator input | |
| Range | 20KHz |
| Measurement type | <500Hz = Period measurement >500Hz = Pulse measurement |
| Excitation | Jumper selectable 5, 12 or 24VDC |
| Max. excitation current | 100 mA |
| Analogue Output: | (menu selectable) |
| Ranges | 0-20mA | 4-20mA | 0-10V |
| DAC Resolution | 16 Bit |
| Update rate | 12 updates/second |
| Current output compliance | 500Ω maximum load | (Current is source, not sink) |
| Voltage output compliance | 1kΩ minimum load |
| Open loop detection | LCD display flashes “mA.Loop” error message |
| Linearity | <0.02% of full scale |
| Accuracy | 0.05% of full scale |
| Communications: | |
| Protocol | MODBUS RTU |
| MODBUS ASCII | |
| ASCII In (Infiniteq Protocol) | |
| ASCII Out (Infiniteq Protocol) | |
| RS232 (standard) | Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Data bits: 7 or 8 bits | |
| Parity: Odd, Even or None | |
| Stop bits: 1 or 2 stop bits | |
| Non isolated | |
| RS485 (optional) | Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Data bits: 7 or 8 bits | |
| Parity: Odd, Even or None | |
| Stop bits: 1 or 2 stop bits | |
| Internal 120Ω field jumper selectable termination resistor | |
| Max 32 instruments per line | |
| Setpoint Relays: | |
| Electro-mechanical: | (4 relays, standard) |
| Contact rating | 2A@240VAC or 30VDC (resistive load) |
| Isolation to input circuitry | >1000Vrms for 1 minute |
| Type | FORM-C (change over contact, NO / NC) |
| Life expectancy | >100K cycles min. at full load rating. External RC snubber extends relay life for operation with inductive loads |
| Solid-State (SSR): | (optional, 1, 2, 3 or 4) |
| Contact rating | 120mA@400VAC/DC |
| Isolation to input circuitry | >1000Vrms for 1 minute |
| Type | FORM-A (Normally open) |
| Real Time Clock: | |
| Battery | CR2032 |
| Accuracy | Better then 3 seconds per day (temperature dependent) |
Order codes and options:
IQ320 for 85-264VAC auxiliary supply
-700 10-30VDC auxiliary supply
-701 25-70VDC auxiliary supply -720 1 solid-state Form A relay -721 2 solid-state Form A relays -722 3 solid-state Form A relays -723 4 solid-state Form A relays -731 16 bit isolated analogue output -762 115VAC inductive load suppressor -763 230VAC inductive load suppressor -764 2A slow blow replacement fuse -765 R-C snubber arc and noise suppressor
IQ320 6-digit wall-mount beltweigher system